249 research outputs found

    A new volar plate DiPhos-RM for fixation of distal radius fracture: Preliminary report

    Get PDF
    We analyzed the efficiency of a new plate DiPhos-RM in CFR-PEEK [carbon-fiber-reinforced poly (etheretherketone)] for the volar fixation of distal radius fractures. The new plate's composition has the advantage of x-ray absolute transparency, therefore allowing to monitor the healing of the fracture. The desired combination of high strength and low rigidity is obtained through the use of the polymer composites CFR-PEEK. In this preliminary study (from March 2012 to June 2012), 10 cases of intra-articular distal radius fractures were treated with DiPhos-RM produced by Lima Corporate (Italy). The fractures were classified according to the AO classification, 4 fractures were type C1, 3 type C2, and 3 were A2. A preoperative computed tomography scan was carried out in all patients. One patient also underwent a postoperative computed tomography scan. Grip strength, range of motion, and DASH score were evaluated at follow-up. There were no cases of hardware failure. Specifically, no loss of position or alignment of fixed-angle locking screws or breakage of the plate were observed. Radiographic union was present at an average of 6 weeks (range, 5 to 8 wk). The overall preliminary experience with this new plate is favorable. The new plate is easy to apply and provides the surgeon dual options of fixed-angle or variable-angle screws. It was rigid enough to maintain the reduction also in AO type C articular fractures. Copyright © 2013 by Lippincott Williams & Wilkins

    Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

    Get PDF
    Background: Multiple techniques for corrective osteotomy have been developed in recent years with the same aims: to improve the radiographic parameters and improve motion, pain and grip strength. Volar fixed-angle plates have added a new concept to the treatment of distal radius fractures thanks to the low morbidity of the surgical approach and the strength of the final construct, allowing early mobilization and return to function.Materials and methods: Between 2005 and 2012, 20 patients with symptomatic dorsally malunited extra-articular fractures of the distal radius underwent corrective osteotomy using a volar locking plate without additional bone graft. At a mean follow-up of 50 months, all the patients were clinically and functionally evaluated.Results: All measurements of pain, final range of motion and grip strength significantly improved compared with preoperative measurements. The mean preoperative DASH score reduced from 54 points preoperatively to 25 postoperatively. Based on the modified Mayo wrist score, we obtained 14 excellent and six good results. Palmar tilt improved from an average of 23° to 11°. Radial inclination improved from an average of 29° to 22°, and ulnar variance decreased from an average of 3.6 mm to 0.9 mm. There were two cases of transient median neuroapraxia that resolved before the 6-week follow-up appointment. No other major complications, including non-union and infection, were observed.Conclusion: The volar approach and locking plate, without necessarily the use of bone grafting, proved to be an effective approach for addressing symptomatic and even severe deformities of the distal radius.Type of study/level of evidence: Therapeutic IV

    Imaging of the Unstable Shoulder

    Get PDF
    Unstable shoulder can occur in different clinical scenarios with a broad spectrum of symptoms and presentations: first-time (or recurrent) traumatic acute shoulder anterior dislocation or chronic anterior instability after repeated dislocations.Imaging in unstable shoulder is fundamental for choosing the right treatment preventing recurrence.The goal of imaging depends on clinical scenario and patient characteristics

    Treatment of the ulna non-unions using dynamic compression plate fixation, iliac bone grafting and autologous platelet concentrate

    Get PDF
    Clinical study of a series of ten patients treated between 2004 and 2009 for non-unions of the ulna. The patients have been treated with osteosynthesis using a dynamic compression plate and biological enhancement of the consolidation using bone graft and autologous platelet injection. The follow-up consisted of clinical and radiographic assessment. Functional scores used were the Visual Analogue Scale (VAS) for pain and the Disability Assessment for the Shoulder and Hand (DASH) questionnaire. The mean time of follow-up was 21 months. Considering both clinical and radiological criteria, bony union was achieved in 9/10 cases on average time of 4 months. According to the system of Anderson, 5 patients provided an excellent result, 2 a satisfactory result, 2 an unsatisfactory result and 1 treatment resulted in failure. At follow-up, the mean VAS score for pain in the upper limb was 1 (range, 0-4) at rest and 2 (range, 0-7) during activities. The physical function and symptoms of the upper limb, evaluated with the DASH questionnaire, scored 17 points. In conclusion, at a mean 21 months follow-up, there was high success regarding both forearm alignment, clinical and functional results. The use of three combined methods provides high success regarding both radiological and clinical results, even if we have no information on the prevalent efficacy of one particular method. © Springer-Verlag 2011

    Ultrastructural aspects of articular cartilage and subchondral bone in patients affected by post-traumatic shoulder instability: preliminary observations

    Get PDF
    Post traumatic shoulder instability is a frequent condition in young active population. Notwithstanding a lot of data have been collected on capsular-legament lesions and gleno-humeral defects, no data are available on early ultrastructural ostheo-condral damages that are known to be highly associated with the onset of invalidating pathologies, like osteoarthritis (OA). Thus, the mechanisms of joint instability and the identification of which components in the articular complex are primarily affected in instability are of clinical significance, particularly in the light of deepening knowledge on the onset/development of OA. In the present study, biopsies of the articular cartilage and sub-chondral bone were taken from 10 patients (aged 26-40) underwent surgery in Policlinico of Modena. The withdrawals were immediately fixed and embedded for Transmission Electron Microscopy (TEM). The observations were performed in tangential, arcuate, and radial layers of the articular cartilage as well as in sub-chondral bone. TEM observations showed that chondrocytes in the superficial layers (i.e. tangential and arcuate) display normal and very well preserved ultrastructure, probably due to synovial liquid supply; otherwise, chondrocytes in the radial layer (not only in calcified but also in the un-calcified one) show various degrees of degeneration, with cytoplasm partially coerced and variously-sized vacuoles, both signs of suffering; occasionally, in the radial layer, chondrocytes with morphological signs of apoptosis or autophagy were also observed. As far as sub-chondral bone is concerned, osteocytes next the deeper calcified cartilage (within 80-100 micra from the cement line) also show evidences of degeneration, while osteocytes more distant from the osteo-chondral border display normal ultrastructure probably due to the vascular bone supply. In all patients of the study, the ultrastructural features of osteo-chondral complex are not depending on age. The present study represents the first ultrastructural investigation of the articular osteo-chondral complex in shoulder instability, evaluating the state of preservation/viability of both chondrocytes and osteocytes throughout the successive layers of the articular cartilage and sub-chondral bone. These preliminary observations are the basis to understand if the early surgical treatment in shoulder instability could avoid the onset of OA

    A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases

    Get PDF
    BACKGROUND: Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at 12-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon for the treatment of distal radius fractures. MATERIALS AND METHODS: We included 40 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the AO classification: 21 fractures were type C1, 9 were type C2, 2 were type C3, 2 were type B1 and 6 were type B2. RESULTS: At a 12-month follow-up no cases of hardware breakage or loss of the surgically achieved fracture reduction were documented. All fractures healed, and radiographic union was observed at an average of 6 weeks. The final Disabilities of Arm, Shoulder and Hand score was 6.0 points. The average grip strength, expressed as a percentage of the contralateral limb, was 92 %. Hardware removal was performed only in one case, for the occurrence of extensor tenosynovitis. CONCLUSION: At early follow-up this device showed good clinical results and allowed maintenance of reduction in complex, AO fractures. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV

    Comparison between absorbable pins and mini-screw fixations for the treatment of radial head fractures Mason type II-III

    Get PDF
    Background: The treatment of comminuted radial head fractures can include prosthetic replacement or open reduction and internal fixation. The purpose of this study is to evaluate the results of two different internal fixation systems for Mason type II-III radial head fractures. Methods: Between 2005 and 2015, 82 patients were treated using pins and 65 patients by mini-screws. The follow-up protocol included: a clinical evaluation 15 days after surgery, and clinical and radiographic evaluations performed at 30 and 60 day intervals, unless any complications were reported by the patient. Over a period of at least 12-months of follow-up, patients were checked and interviewed. Clinical examinations included elbow range of motion (ROM), arm, shoulder and hand Disabilities, (DASH), and the Mayo Elbow Performance Score (MEPS). Results: Sixty-one subjects who had been treated with mini-screws were clinically reviewed at a mean 47.3 \ub1 35.8 month of follow-up; all patients who had been treated using absorbable pins were evaluated at a mean 82.5 \ub1 20.6 month of follow-up. No significant statistically differences were observed between the two groups in the mean ROM, DASH, and MEPS scores. Residual pain was reported in 15.8%of the patients treated by pins and 9.2% patients treated by mini-screws. Secondary displacement of fracture fragments was observed in 8.5% patients treated by pins and 1.6% using mini-screws. Conclusions: Both absorbable pins and mini-screws provided adequate strength and rigidity, allowing good clinical and functional scores at a mid-term follow-up. However, a higher rate of secondary displacement of the fracture fragments was reported among subjects who had been treated using absorbable pins

    Volar plate fixation for the treatment of distal radius fractures: Analysis of adverse events

    Get PDF
    OBJECTIVES:: Determining the rate of specific adverse events after volar plating performed for distal radius fractures. DESIGN:: Retrospective. SETTING:: University level I trauma center. PATIENTS:: We searched the electronic database of all surgical procedures performed in our department using the following keywords: distal radius fracture, wrist fracture, and plate fixation. We identified 315 patients, 12 of whom were lost at follow-up. INTERVENTION:: Volar plate fixation for the treatment of distal radius fractures. MAIN OUTCOME MEASUREMENTS:: At an average follow-up of 5 years, 303 patients were evaluated through medical records and clinical and radiographic assessment for specific adverse events after volar plate fixation. RESULTS:: Adverse events were observed in 18 patients (5.9%). Implant-related adverse events, including tendon impairments, intra-articular screws, and screw loosening, were observed in 15 patients (5.0%). Extensor tendon impairments were represented by 5 cases of extensor tenosynovitis and 3 cases of rupture of the extensor pollicis longus due to screws protruding dorsally. Flexor impairments were represented by 2 cases of tenosynovitis and 2 cases of flexor pollicis longus rupture. Screw penetration into the radioulnar joint was observed in 1 case. Loss of reduction was identified in 3 cases. One patient had a deep postoperative infection treated with operative debridement. One patient experienced injury to the median nerve during routine implant removal unrelated to tendon issues. CONCLUSIONS:: The majority of adverse events after volar plate fixation were due to technical errors in implant placement. In our cohort, tendon impairments were the most frequently observed; among these, extensor tendon impairments were the most represented (50% of all adverse events). All 12 tendon-related adverse events were due to technical shortcomings with implant placement. LEVEL OF EVIDENCE:: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. © 2013 Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited

    QCD radiative corrections to prompt diphoton production in association with a jet at hadron colliders

    Get PDF
    We compute the next-to-leading order corrections in αs\alpha_s to prompt diphoton production in association with a jet at hadron colliders. We use a next-to-leading order general-purpose partonic Monte Carlo event generator that allows the computation of a rate differential in the produced photons and hadrons.Comment: 17 pages, 6 figures, JHEP3 documen
    • …
    corecore